Troubleshooting

Find the first step that fails, from opening the file to reading a value, and fix it there before changing anything else.

Work from the top. A problem early in the chain, such as a log with no CAN frames or a DBC on the wrong channel, shows up later as missing or wrong values. See How decoding works for the full chain.

What you seeFirst check
Frames are visible but no signals can be addedOpen channel mapping and check that a DBC is linked to the channel carrying the frames.
The signal is listed but has no curveSelect Start parsing, then check that the message occurs on that channel.
The curve is visible but its values look wrongCheck the raw bytes and DBC definition for the same channel and message ID.

The file does not open

  • Larger than 150 MiB. The workbench rejects it before reading. Split the log, or use a smaller capture. See Limits.
  • A Windows .blf. Windows' Common Log File System also uses .blf, but it is a system log, not a CAN log.
  • An MF4 without CAN bus logging. A measurement-only MDF file, an unfinalized recording, or an unsupported block or compression method cannot be read. Export the recording as BLF or ASC from the tool that wrote it.
  • "Unrecognized CSV header." The CSV reader expects python-can columns, or a header with time, ID, data and optionally channel columns. See Supported files.

The log opens, but there are no channels or frames

The file holds no CAN, CAN FD or LIN frames the readers recognise. FlexRay and Ethernet objects are skipped. Check the file in the tool that recorded it.

There are frames, but no signals to add

  • No DBC is mapped. Add a DBC and check File → Channel mapping…. Start parsing stays unavailable until at least one channel has a DBC.
  • The DBC describes a different bus. A DBC added from the File menu is linked only to channels where its message IDs occur. If it ended up on no channel, none of its IDs are in the log. In the Frames view, expanding a frame shows when no mapped DBC defines its ID on that channel.

A signal is in the table, but its curve is empty

  • It was added after the last parse. Only plotted signals are decoded. Select Start parsing again.
  • Its message is not on that channel. A signal belongs to a channel and message, so check that the message ID really appears on the channel the DBC is mapped to.
  • It is multiplexed. A multiplexed signal only has values in frames where its multiplexor value occurs.

A value looks wrong

Trace the number back to the bytes, in this order:

  1. Channel and DBC. Is the right DBC on the channel that recorded the frame? If a channel has several DBCs, the first one in its list that defines the ID wins. See Channel mapping.
  2. Byte order and signedness. An Intel signal read as Motorola, or the reverse, gives large, jumpy values. An unsigned signal that should be signed shows negative values as large positive numbers.
  3. Factor and offset. These can change between ECU software versions. Make sure the DBC matches the software that was running when the log was recorded.
  4. J1939. With 29-bit IDs, check the PGN and source address of the frame against the DBC message.

The signal calculator decodes one payload by hand, so you can compare it with the graph. Intel vs Motorola byte order explains the most common mistake. The DBC checker finds definition errors, such as overlapping signals, that give wrong values without any warning.

Name search in the Frames view finds nothing

Message, node and signal names come from the DBC. Map the channel and run Start parsing before you search by name. Searching by ID works without a DBC.

The Frames view ends before the log does

The Frames view lists only the first 120,000 frames of a log, and filters work within those. Later frames are still decoded, so their signals appear in the graph and in exports. To read the raw frames of a later part, cut that part out of the log first, for example with the ASC splitter for ASC files, and open it on its own.

Chinese text in a DBC is garbled

DBC files are read as UTF-8 and fall back to GBK/GB18030. A file in another encoding, such as Big5 or Shift-JIS, can still come out garbled. Re-save it as UTF-8 in a text editor and add it again.

A project reopens without its signals

A project file stores settings, not data. Pick the same log and DBC files again; DBCs are matched by file name. The signal layout returns after the next parse. See Open a log.

Parsing is slow

Large logs can take a while, especially with many channels and signals. Plot fewer signals, close other heavy tabs, and use Stop in the toolbar if you need to change the setup.

Still stuck

Open a ticket in Settings → Support Tickets or use Feedback at the bottom right of the page. Include the log format, its size, and what you expected to see.