Quickstart

Go from a CAN log file to a decoded signal on a chart. Open the log, add its DBC, map each channel, and plot. About five minutes, nothing to install.

Decode your own log with its matching DBC, or open the sample drive and jump to reading the chart. The sample is a synthetic two-channel capture with its DBC mapped and signals plotted.

To practice the full workflow with the same files, download sample-drive.asc and demo-vehicle.dbc.

Before you start

You need two files.

  • A log: one capture of bus traffic, with a timestamp, channel, ID and data bytes for every frame.
  • A DBC: the database that turns frame IDs and bytes into named signals with a factor, an offset and a unit. Without one you can still read raw frames, but not physical values.

The workbench reads these log formats:

FormatExtensionTypically written by
BLF.blfVector CANoe, CANalyzer and Vector loggers
MF4.mf4Loggers that write ASAM MDF 4.x
ASC.ascVector ASCII trace export
CSV.csvFrame tables exported from other tools
candump.logLinux SocketCAN (candump -l from can-utils)

A log can be up to 150 MiB. DBC files in UTF-8, GBK or GB18030 are detected automatically, so Chinese comments and value tables read correctly.

To look through one file before you set up a decode, the BLF viewer and MF4 viewer open it with no DBC. If your logs come from CANoe, how to open a BLF file without CANoe walks through the same steps with a BLF.

Your files stay on this computer

The log and the DBC are decoded inside this browser tab by a Web Worker. Saving a cloud project sends settings and file names. Uploading the log or DBC is a separate action. See Data and privacy.

Decode your first log

Open the log

Open the workbench, choose File → This computer → Log…, and pick your log. If the first-visit tour opens, select Skip to follow this guide. When the scan finishes, the top of the File menu shows the log name and channel count. Switch to Frames if you only need to inspect raw traffic.

The File menu with Log and DBC under This computer
Open the log and DBC from the This computer section of the File menu.

Add a DBC

Choose File → This computer → DBC… and select one or more .dbc files. The workbench suggests channel links based on the message IDs it finds in the log. Check those links in the next step.

If you need a database, OpenDBC library… is in the same menu. Check a known reading before relying on a community DBC.

Review and save the channel mapping

Open File → Channel mapping… and expand the channel you want to analyse. Check that the correct DBC appears underneath it. To correct a link, unlink the existing DBC and drag the correct one onto the channel, or use Link a DBC on its row. With the downloadable sample, both channels should list demo-vehicle.dbc.

Select Save Mapping to return to the workbench. If a channel uses several DBCs, see the example in Channel mapping to check their order.

Channel Mapping showing demo-vehicle.dbc linked to channels 1 and 2
The sample uses the same DBC on both channels. Link a DBC and Save Mapping are on the right.

Select a signal

Switch to Signals and select Add Signal. Search by signal name, check the channel and message, select a signal, then choose Done. With the sample files, try VehicleSpeed on channel 1. The signal appears in the table on the left.

Start parsing

Select Start parsing in the toolbar. When parsing finishes, the selected signal appears on the chart. After adding another signal, select Start parsing again. If the button is unavailable or the curve stays empty, use Troubleshooting to check the mapping and message.

The workbench with VehicleSpeed selected and the Start parsing button in the toolbar
The signal is in the table. Select Start parsing to draw its curve.

Read the chart

You can practice on the sample drive. Select Box zoom and drag a rectangle around part of a curve. Place the main cursor, move it to the time you want to inspect, and read the value in the table's y column. To compare two moments, follow the two-cursor example in Signal graph.

The Signals view with several decoded signals plotted on a shared time axis
The Signals view after a log and its DBC have been parsed.

Check a value against the raw frame

A decoded number is only as good as the DBC behind it. When a value looks wrong, trace it back to the bytes.

  1. Open the Frames view. It lists every frame as recorded: time, channel, ID, DLC and data bytes in hex.
  2. Filter by the ID of the message that carries the signal.
  3. Open the DBC view and select the same message to see the signal's start bit, length, byte order, factor and offset.
The Frames view listing raw CAN frames with time, channel, ID, DLC and data bytes
The Frames view shows every raw frame, whether or not a DBC decodes it.

Most wrong values come from one of three things: the wrong DBC on a channel, an Intel signal read as Motorola (or the reverse), or a factor and offset that do not match the ECU software version.

Save or export your work

  • Save the session. File → Save project, then This computer, writes a small .blfproject.json project file with the log name, the DBC names, the channel mapping and the signals on the chart. Keep the project file together with the original log and DBC files.
  • Export data. File → Export offers Signals (CSV) for the signals on the chart, All decoded signals (CSV), Chart image (PNG) and Diagnostics report (PDF). See Save and export.

Next steps