Frame trace

Read raw frames as recorded, find one ID or byte pattern with filters and queries, and expand a frame to see its decoded signals next to the bits.

The Frames view lists the log's frames in recorded order: time, channel, ID, direction, DLC and data bytes. It works without a DBC. Once channels are mapped and parsed, each row also shows its message and sending node from the DBC. To browse one BLF file's frames without setting up the workbench, use the BLF viewer.

The bar above the table shows how many frames are shown, the total and the time span of the log.

Up to 120,000 frames

The Frames view holds the first 120,000 frames of a log. Signal decoding, the graph and exports still cover the whole file.

Reading a row

ColumnShows
Time (s)Seconds from the start of the log
CHChannel, with its own colour tag
IDArbitration ID in hex
PGNJ1939 parameter group, for 29-bit IDs
Message, NodeMessage name and sending node from the mapped DBC
DirRx or Tx
DLCData length
CycleCycle time the DBC defines for the message
DataPayload bytes; 00 bytes are dimmed so the bytes that carry values stand out
SparkHow the first byte changes over the log

Find a frame

  • Find ID jumps between rows with that ID. Use the previous and next buttons to step through matches.
  • Find frame or signal name does the same by message or signal name.

Filter

Filter opens the full filter. The header shows how many frames match while you edit, before you apply anything.

The Filter frames panel over the frame table, with channel, direction, frame type, message, node, ID and time fields
The filter panel. The count at the top right updates as you change the fields.
FieldHow to use it
ChannelsClick the channel chips to choose which channels to show
DirRx, Tx or both
Frame typeCAN, CAN FD, LIN, ERR
Message, NodeNames from the DBC; * is a wildcard, as in ESP_*
IDIDs and ranges in hex, such as 100, 1A0-1FF; then Only or Hide
Time (s)From and to, in seconds from the log start or as HH:MM:SS.mmm; both ends inclusive
Advanced: data bytes and queryA byte pattern found anywhere in the payload (?? matches any byte, as in 22??90), and the query box below

Select Apply filter to use it, or Reset to clear the fields. Active filters appear as chips above the table. Remove one by its chip, or use Clear all.

Advanced query

The query box combines everything in one line:

KeyExampleMatches
idid:100,1A0-1FFIDs and ranges, hex
chch:1,2Channels
tt:1.5..3Time range in seconds
msg / nodemsg:ESP_*Message or node name; * is a wildcard
datadata:22??90Byte pattern
dlcdlc:..8DLC or range
typetype:fdcan, fd or err
dirdir:txrx or tx
sigsig:EngineSpeed>6000A decoded signal value

Terms separated by spaces must all match. Commas inside a term mean "or", and a leading - excludes, as in -ch:2. sig compares numbers with == != < <= > >=. It compares text labels with == or !=, as in sig:Gear==Second.

Expand a frame

Select Expand on a row to see every signal the DBC defines in that message. Each signal is shown with its value, unit, meaning (the value-table label), description, raw value and the bits it occupies. How decoding works explains how each value is computed.

If no mapped DBC defines the ID on that channel, the row says so. Link the right DBC in Channel mapping. LIN frames show their payload as logged, without decoding.

To copy a row or its decoded signals, use Copy.