Frame trace
Read raw frames as recorded, find one ID or byte pattern with filters and queries, and expand a frame to see its decoded signals next to the bits.
The Frames view lists the log's frames in recorded order: time, channel, ID, direction, DLC and data bytes. It works without a DBC. Once channels are mapped and parsed, each row also shows its message and sending node from the DBC. To browse one BLF file's frames without setting up the workbench, use the BLF viewer.
The bar above the table shows how many frames are shown, the total and the time span of the log.
Up to 120,000 frames
The Frames view holds the first 120,000 frames of a log. Signal decoding, the graph and exports still cover the whole file.
Reading a row
| Column | Shows |
|---|---|
| Time (s) | Seconds from the start of the log |
| CH | Channel, with its own colour tag |
| ID | Arbitration ID in hex |
| PGN | J1939 parameter group, for 29-bit IDs |
| Message, Node | Message name and sending node from the mapped DBC |
| Dir | Rx or Tx |
| DLC | Data length |
| Cycle | Cycle time the DBC defines for the message |
| Data | Payload bytes; 00 bytes are dimmed so the bytes that carry values stand out |
| Spark | How the first byte changes over the log |
Find a frame
- Find ID jumps between rows with that ID. Use the previous and next buttons to step through matches.
- Find frame or signal name does the same by message or signal name.
Filter
Filter opens the full filter. The header shows how many frames match while you edit, before you apply anything.

| Field | How to use it |
|---|---|
| Channels | Click the channel chips to choose which channels to show |
| Dir | Rx, Tx or both |
| Frame type | CAN, CAN FD, LIN, ERR |
| Message, Node | Names from the DBC; * is a wildcard, as in ESP_* |
| ID | IDs and ranges in hex, such as 100, 1A0-1FF; then Only or Hide |
| Time (s) | From and to, in seconds from the log start or as HH:MM:SS.mmm; both ends inclusive |
| Advanced: data bytes and query | A byte pattern found anywhere in the payload (?? matches any byte, as in 22??90), and the query box below |
Select Apply filter to use it, or Reset to clear the fields. Active filters appear as chips above the table. Remove one by its chip, or use Clear all.
Advanced query
The query box combines everything in one line:
| Key | Example | Matches |
|---|---|---|
id | id:100,1A0-1FF | IDs and ranges, hex |
ch | ch:1,2 | Channels |
t | t:1.5..3 | Time range in seconds |
msg / node | msg:ESP_* | Message or node name; * is a wildcard |
data | data:22??90 | Byte pattern |
dlc | dlc:..8 | DLC or range |
type | type:fd | can, fd or err |
dir | dir:tx | rx or tx |
sig | sig:EngineSpeed>6000 | A decoded signal value |
Terms separated by spaces must all match. Commas inside a term mean "or", and a leading - excludes, as in -ch:2. sig compares numbers with == != < <= > >=. It compares text labels with == or !=, as in sig:Gear==Second.
Expand a frame
Select Expand on a row to see every signal the DBC defines in that message. Each signal is shown with its value, unit, meaning (the value-table label), description, raw value and the bits it occupies. How decoding works explains how each value is computed.
If no mapped DBC defines the ID on that channel, the row says so. Link the right DBC in Channel mapping. LIN frames show their payload as logged, without decoding.
To copy a row or its decoded signals, use Copy.
Signal graph
Add and arrange signals, group them, move or scale a single curve on its own axis, zoom in time and value, and measure with two cursors.
DBC view
Inspect every loaded DBC inside the workbench, including messages, signal definitions, bit layout, value tables, attributes, nodes and network settings.